Interferential Therapy Equipments (IFT)
Interferential therapy (IFT) has been practiced for a very long time in Physiotherapy to treat various disorders, inflammation/pain etc., including stiffness in joints, body pain, muscular and circulatory disorders, cumulative trauma disorders, inflammation, edema, post orthopedic surgeries, etc. Studies show that patients choosing to undergo interferential therapy treatment have fewer postoperative complications compared to people who rely exclusively on medication for pain relief. The therapy also helps in blood circulation and hastens the healing process by stimulating “endorphins” Numerous case studies and research have been documented for the effectiveness of Interferential l therapy all over the world. Our interferential therapy Equipment designed for physiotherapy are highly capable of delivering superior, precise and safe interferential therapy to the patients.
Premium Electrotherapy 4 Channel Equipment
UNISTIM® 5n
The UNISTIM 5n is a premium electro therapy. It has four different channels for electrotherapy applications. In the development of the unit simplicity of operation and functionality were the principal consideration. All the available types of current and therapy are clearly displayed on a 5″ Colour touch screen. The intensity can be easily set with encoder. Pre-programmed memory with treatment applications offers protocols for more than 77 frequently occurring indications. And users can store their settings in user memory.
- Both medium and low frequency currents
- Electro therapy-1 and Electro therapy-2 can be used simultaneously and individually
- Can treat 2 patients simultaneously
- 77 Pre-programs with condition wise protocols
- Cable and electrode checking mode
- Illustration image for Electrode placement
- User settable memory with patient name
- Encoder for intensity
- Light weight and compact design
- Easy to operate
- Plastic cabinet
- 5″ Colour Touch Display
- International standards and specifications
- Advanced patient safety system
- Independent intensity variation for each Channels
- 4 Channel for Electro Therapy
- Model : UNISTIM 5n
- Operation Mode : Electrical
- Usage : Clinical, Hospital, Personal
Interferential
- Carrier frequency – 2000Hz – 4000Hz(100Hzstep), 4000Hz – 10000Hz(500Hzstep)
- Base frequency – 1-250Hz(1Hzstep)
- Sweep frequency – 0-250Hz(1Hz step)
- Sweep modulation Programs – 1/1S ,5/1/5S ,6/6S
- Therapy Modes – Four pole Classic, Four pole Vector 90degree , Four pole Vector 45degree , Two pole pre-modulated
Russian current
- Frequency – 2000Hz – 4000Hz(100Hzstep), 4000Hz – 10000Hz(500Hzstep)
- Modulation – Constant/ Surge
- Ramp Rise/Fall – 1-10Sec(1Secstep)
- Burst – 30-250Hz(1Hzstep)
- Hold ON – 1-99Sec(1Secstep)
- Hold OFF – 1-99Sec(1Secstep)
Muscle stimulator currents
- Plain galvanic – Continuous DC current
- Int. galvanic – Diagnostic-0.01, 0.03, 0. 1, 0.3, 1, 3, 10, 30, 100, 300, 1000mSec Therapeutic -30-300mSec (10mSecs)
Diadynamic currents
- DIADYNAMIC CURRENTS – DF, MF, CP, LP, RS, MM
VMS(Vibratory Motor Stimulation)
- Frequency – 2-250Hz
- Waveform – Inverted Symmetric
- Pulse width – 20-400µs
Faradic
- Freq./p.width – 50hz/0.7 msec.
- Surge ontime – 1-10 sec.(in 1 sec step)
- Surge offtime – 1-10 sec.(in 1 sec step)
Tens
- Frequency – 2-250 Hz (in Hz variation)
- Pulse Width – 20-400 µsec(in 1µsec variation)
- Burst Frequency – 1-10Hz
- Sweep Frequency – 2-245Hz to 7-250Hz
- Waveform – Symmetric/Asymmetric/ Alternating/ Monophasic
- Modes – Continuous/ Burst/ Sweep burst & Sweep
Ultra reiz
- Frequency – 142.8Hz
- ONTime – 2 msec
- OFFTime – 5 msec
HV Pulse Current
- Frequency – 1-200Hz(1Hz step)
- Pulse width – 100µs
- Type – Constant/Surge
Micro Current
- Frequency – 1-1000Hz
- Intensity – 10µA-1000µA
Iontophoresis
- Dosage – 2-150mA/min (2mA/min step)
- Intensity – 1-5mA(0.5mAstep)
- Type – Constant/lnterrupted
- Display – 5″ Colour Resistive Touch Display
- Mains Voltage – 100-240V/50/60Hz,
- Safety Class – Class 1, Type BF(lEC60601-1)
- Dimensions – LxBxH-30x25x11.5cms
- Weight – 2.6 Kgs
Computerized Interferential Therapy Equipment
DIGIMED® 301
The DIGIMED 301 is an advanced interferential therapy equipment in the field of electrotherapy. DIGIMED 301 is combination of Interferential, Russian current and TENS. In the development of the unit simplicity of operation and functionality were the principal consideration . All the available types of current and therapy are clearly displayed on a large lcd screen. The corresponding parameters are easily set with five soft touch keys. Pre-programmed memory with treatment applications offers protocols for more than 55 frequently occurring indications. And users can store their settings in user memory locations and easily recall their programme for their patients.
- International standards and specifications
- 55 pre-programme condition wise with products
- Cable and electrodes checking mode
- User settable memory
- Light weight and compact design
- Easy to operate
- Future upgrade without change in hardware
- DSP based circuitry outputs are in 100 % accuracy
- Large graphic LCD display
- Advanced patient safety system
- Model : DIGIMED 301
- Operation Mode : Electrical
- Usage : Clinical, Hospital, Personal
- Carrier frequency – 2000 Hz / 4000 Hz
- Base frequency – 1-150 Hz (1 Hz step)
- Sweep frequency – 1-150 Hz (1 Hz step)
- Sweep Modulation
- Programs – 1 /1S, 1/5, 1/5S, 6/6S
- Therapy Modes – Four pole Interferential, Four pole Vector 90°, Four pole Vector 45°, Two pole pre-modulated
- Output current – 0 – 100 mA
- Timer – 0 – 60 mins
- Mains voltage – 90-270v/50/60hz
- Safety class – Class 1, Type BF (IEC60601-1)
- DIMENSIONS – Lxbxh – 30x25x10.5 cms
- Weight – 2.5 kgs
Premium Combo Electrotherapy Equipment
UNISTIM® 5s
HMS Medical Systems proudly presents UNISTIM® 5s an advanced interferential combination therapy equipment. It has more than six different types of electrotherapy applications such as Interferential, Russian, Tens, etc. All the available options such as types of current and types of therapy are clearly displayed on the large LCD screen. Five Soft Touch keys helps to set required parameters and settings. UNISTIM® 5s has pre-programmed settings with treatment applications offering protocols for more than 77 frequently occurring indications and therapies as well as custom settings to store in user memory.
- Both medium and low frequency Currents
- Russian stimulation
- 77 pre-programs and condition wise with protocols
- Cable and electrode Auto fault detection
- User settable memory
- Soft touch(capsense) keys
- Lightweight and compact design
- Easy to operate
- Plastic moulded cabinet
- Large graphic LCD display
- International standards and specifications
- Advanced patient safety system
- Output mode CC/CV
- Independent intensity controls for each channel
- Model : UNISTIM 5s
- Operation Mode : Electrical
- Usage : Clinical, Hospital, Personal
Interferential
- Carrier frequency – 2000hz/4000hz
- Base frequency – 1-150 hz (1hz step)
- Sweep frequency – 0-150 (1hz step)
- Sweep modulation program – 1/1s 1/5, 1/5s 6/6s
- Therapy Modes – Four pole interferential, Four pole vector 90°, Four pole vector 45°, Two pole pre-modulated
Russian current
- Frequency – 2500 hz
- Ramp rise/fall – 1-10 sec(1sec step)
- Burst – 50-250hz(10hz step)
- Hold on – 1-99 sec(1sec step)
- Hold off – 1-99 sec(1sec step)
Muscle stimulator currents
- Plain galvanic – Continuous DC Current
- Int.galvanic – Diagnostic – 0.01, 0.03, 0.1, 0.3, 1.3, 10, 30, 100, 300 msec(in 10 msec variation) Offtime – 500, 1000, 2000 msec.
Faradic
- Freq./p.width – 50hz/0.7 msec.
- Surge ontime – 1-10 sec.(in 1 sec.variation)
- Surge offtime – 1-6 sec.(in 1 sec.variation)
Tens
- Frequency – 2-250hz(in hz variation)
- Pulse width – 20-250 sec (In 1 sec variation )
- Burst Frequency – 1-10hz
Ultra reiz
- ONTime – 2 msec
- OFFTime – 5 msec
Low Frequency Alternating current
- Diadynamic currents – DF, MF, CP, LP, RS, MM
- TIMER – 0-60 MINUTES
- DISPLAY – 128X128 GRAPHIC BACKLITE LCD DISPLAY
- Mains voltage – 90-270v/50/60hz
- Safety class – Class 1, Type BF (IEC60601-1)
- DIMENSIONS – Lxbxh – 30x25x11.5 cms
- Weight – 3.2 kgs
Mini Digital Interferential Therapy Equipment
INDOMED® D
Our Mini Digital Interferential Therapy Equipment- INDOMED D, provides simplified operation and excellent functionality. The types of current and therapy modes can be viewed in the LCD screen provided. The corresponding parameters can be set by using Nine soft touch keys. Our equipment provides a smooth and error-free operation.
- International standards and specifications
- Auto fault detection of Cable and Electrodes
- Easy to operate
- Light weight and compact design
- DSP based circuitry
- Outputs are in 100 % accuracy
- Large LCD display
- User settable Memory
- Universal input voltage 90v-270v
- Independent Intensity control in 2 pole mode
- Advanced patient safety system
- Model : INDOMED D
- Operation Mode : Electrical
- Usage : Clinical, Hospital, Personal
- Carrier frequency – 2,4,6,8,10 KHz
- Base frequency – 1-150 hz ( 1 hz step )
- Sweep frequency – 0-150 hz ( 1 hz step )
- Sweep modulation programs – 1/1 sec, 1/5/1/5 sec. 6/6 sec
- Therapy modes – four pole interferential, four pole vector 90 degree, two pole premodulated
- Output current – 0-100 mA
- Timer – 0-99min.
- Mains voltage 90-270v/50 or 60 hz
- Safety class i, type bf according to IEC 60601-1
- Dimensions lx bx h 23x 20x 8 cms.
- Weigth 1.6Kg
Model Comparison of HMS Interferential Therapy Equipment
PARAMETERS | INDOMED® D | DIGIMED® 301 | UNISTIM® 5s |
---|---|---|---|
INTERFERENTIAL | ✔ | ✔ | ✔ |
Carrier frequency | 2,4,6,8,10 KHz | 2000Hz / 4000Hz | 2000Hz / 4000Hz |
Base frequency | 1 – 150Hz (1 Hz step) | 1 – 150Hz (1 Hz step) | 1 – 150Hz (1 Hz step) |
Sweep frequency | 0 -150 Hz (1 Hz step) | 1 -150 Hz (1 Hz step) | 0 -150 Hz (1 Hz step) |
Sweep modulation | ✔ | ✔ | ✔ |
Programs | 1/1S, 5/1/5S, 6/6S | 1/1S, 5/1/5S, 6/6S | 1/1S, 5/1/5S, 6/6S |
Therapy modes | Four pole Interferential, Four pole vector 90°, Four pole vector 45°, Two pole pre-modulated. | Four pole Interferential, Four pole vector 90°, Four pole vector 45°, Two pole pre-modulated. | Four pole Interferential, Four pole vector 90°, Four pole vector 45°, Two pole pre-modulated. |
RUSSIAN CURRENT | X | ✔ | ✔ |
Frequency | X | 2500Hz | 2500Hz |
Ramp rise/fall | X | 1 -10 sec (1 sec step) | 1 -10 sec (1 sec step) |
Burst | X | 50 – 250 Hz (10Hz step) | 50 – 250 Hz (10Hz step) |
Hold on | X | 1 -99 sec (1 sec step) | 1 -99 sec (1 sec step) |
Hold off | X | 1 -99 sec (1 sec step) | 1 -99 sec (1 sec step) |
MUSCLE STIMULATOR CURRENTS | X | X | ✔ |
Plain galvanic | X | X | Continuous DC current |
Int. galvanic | X | X | Diagnostic & therapeutic |
FARADIC | X | X | ✔ |
Freq. / p.width | X | X | 50Hz/0.7 msec |
SURGE FARADIC | |||
Surge on time | X | X | 1 -10 sec (1 sec step) |
Surge off time | X | X | 1 -6 sec (1 sec step) |
SURGE FARADIC | X | X | X |
Surge on | X | X | X |
TENS | X | ✔ | ✔ |
Frequency | X | 2 – 250 Hz | 2 – 250 Hz |
Pulse width | X | 20 -250 sec | 20 -250 sec |
Burst frequency | X | 1 – 10Hz | 1 – 10Hz |
Program | X | X | 77 pre-sets |
Ultra reiz | X | X | ✔ |
ON time | X | X | 2 msec |
OFF time | X | X | 5 msec |
LOW FREQUENCY ALTERNATING CURRENT | X | X | ✔ |
Diadynamic currents | X | X | DF, MF, CP, LP, RS, MM |
Timer | 0 – 99 mins | 0 – 99 mins | 0 – 99 mins |
Display | LCD 4×20 | LCD 128×64 | LCD 128×128 |
Output current | 0 – 100mA | 0 – 100mA | 0 – 100mA |
Memory | 10 | 30 | 30 |
Power | Mains (100 -240V) | Mains (100 -240V) | Mains (100 -240V) |